The direction of an electric charge that is flowing in a circuit is constantly being reversed back and forth.
Amp (ampere)
The standard unit of measure for electrical current, defined as the amount of electrical flow equal to one coulomb per second.
Apparent Power
The product of the applied voltage and current in an AC circuit.
Blackout
A power failure in which line voltage drops to zero.
Brownout
A drop in voltage in electrical power supply.
Buck/Boost
Full automatic voltage regulation in a UPS stabilizes low voltage (boost) and high voltage (buck) to maintain nominal 230V power, without resorting to battery power when minor power fluctuations occur.
Coaxial Cable
Cables that are made of an inner conductor surrounded by an insulator and a shield that are generally used for TV antennas, satellite dishes, cable modems and certain computer networking applications.
Current
The flow of electric charge, measured in amps.
DHCP
Dynamic Host Configuration Protocol (DHCP), automatically assigns an IP address to a device on a network.
Direct Current (DC)
The unidirectional flow of a electric charge.
Double-Conversion UPS
This high-end UPS system converts incoming utility AC power into DC power and then back into AC power, charging connected devices with the UPS battery. The isolated process ensures clean and stable output voltage and zero transfer time. This UPS system is ideal for equipment sensitive to power fluctuations such as corporate data centers, servers, and network and storage devices.
Efficiency (Energy Conversion Efficiency)
The ratio between the amount of apparent power and the amount of true power used by an electrical device. The closer the true power value is to the apparent power, the more efficient the device.
Electromagnetic Interference (EMI)
Commonly referred to as line noise, these interference signals can disrupt or degrade the performance of a circuit by inserting abnormalities into the system. Also referred to as radio frequency interference (RFI) when in high or radio frequency.
Frequency
The number of cycles in a given time period, which is measured in Hertz.
Ground
An electrical system connection that serves as a conduit between the circuit and earth.
Half-Load
The midpoint in the maximum load capacity for a UPS.
Hard-wired
High amperage devices that require installation by a qualified electrician to be directly wired-in, instead of simply being plugged in to an outlet.
Hertz (Hz)
The unit for frequency, defined as the number of cycles per second.
Hot-Swappable Battery
A term used to describe the functions of replacing a UPS battery without shutting down the unit.
Joule
A measure of electrical energy — one joule is defined as the energy needed to pass one ampere of current through one ohm of resistance.
Line-Interactive UPS
Functions the same as a standby UPS, with the additional feature of some voltage regulation built in. It switches to battery power when voltage drops too low, just as a standby UPS does, however if the voltage only drops slightly, a line-interactive UPS corrects this without using battery power. The functionality of these mid- to high-grade units falls between standby and online UPS units.
Load
The amount of power consumed by an electrical device on a circuit. Load capacity is a critical factor in selecting a UPS or surge protector.
MOV
Metal Oxide Varistor is an electronic component that is used to protect circuits against excessive, short-lived, voltages.
Nominal Voltage
The standard voltage for a circuit or system. Common nominal voltages in the U.S. include 120VAC, 208VAC and 240VAC; while nominal voltage in the EU is 230VAC.
Overvoltage
This occurs when incoming voltage is higher than normal but not high enough to be classified as a surge.
Power Factor (PF)
The ratio of real power (watts) to apparent power (VA), expressed as a number between 0 and 1. Watts divided by VA = Power Factor
Power Factor Correction
Controls the incoming power to a power supply in order to bring the power factor as close to unity power as possible.
Radio Frequency Interference (RFI)
See Electromagnetic Interference.
Real Power
The amount of power being drawn by a system, measured in watts. Real power is a function of VA (apparent power) and the power factor.
RJ11, RJ14, RJ45
The abbreviation of registered jack (RJ) – RJ11 is for standard phone lines, RJ14 is for multiple phone lines and RJ45 is for Ethernet.
Runtime
The maximum period of time battery power is output from a UPS to its connected devices during a power interruption. Runtime is dependent upon the total load of all connected equipment.
Simulated Sine Wave
A modified or approximated sine wave AC power output. Simulated (or nonsinusoidal) waveforms may also be referred to as a squared sine wave, modified sine wave, trapezoidal sine wave or quasi sine wave.
Sine Wave
A smooth, repetitive oscillation of AC power.
Single Phase Power
Refers to the distribution of alternating current electric power using a system in which all the voltages of the supply vary in unison.
SMTP
Simple Mail Transfer Protocol is the standard for e-mail transmission on the Internet
SNMP
Simple Network Management Protocol is a commonly used protocol for devices to communicate over a network.
Spike
A spike is a sudden, brief power surge, usually lasting less than 1ms.
Standby UPS
A UPS that passes utility power straight through to the output when conditions are stable, but switches to battery power when utility voltage drops below an acceptable level.
Surge
Periods when line voltage increases dramatically, typically lasting longer than 1ms, but less than a few seconds, though they can last longer.
Total Harmonic Distortion (THD)
A calculated measure of the reduction in sine wave clarity caused by stray wave frequencies.
Thermal Dissipation
The process of dissipating heat from an electrical system via air or liquid cooling; also a term for the amount of heat a device can emit.
Transfer Time
The time it takes UPS to switch from AC power to battery power.
Transformer
A device that converts AC line voltage to a higher or lower value.
U
The standard unit of measure for rack-mounted equipment. A device measuring 1U is 1.75 inches high, 2U is 3.50 inches, etc.
Undervoltage
Related to both brownout and voltage sag, undervoltage falls between these two, occurring when voltage is lower than normal for an extended period of time without recovering, but not to low that the electronic device will not function.
USB (HID Compliant)
Universal Serial Bus devices are used to connect various components to a computer. An HID (Human Interface Device) compliant USB follows a specific protocol for communication that allows it to be used with virtually any system.
Volt
The difference in electric potential between two points when one amp of current dissipates one watt of power.
Volt-Ampere
The unit used to express apparent power.
Voltage Regulator
A device or component that normalizes voltage to a certain standard when it is fluctuating.
Watt
A unit of measure for true power consumption.
Waveform
Is a representation (or form) of how alternating current (AC) varies with time. Common waveform representations include sine wave, square wave and trapezoidal wave. An instrument called an oscilloscope can be used to visually represent a wave as a repeating image on a screen.
Wiring-Fault
Refers to an abnormal flow of current that is due to an improperly grounded electrical outlet.
Top Tìm Kiếm
Chuyên Gia Giải Pháp Năng Lượng
CRN Data Center 100 vàTop 20 Nhà Cung Cấp Cơ Sở Hạ Tầng
Phát triển nhanh với giải pháp doanh nghiệp
GreenPower UPS™ Energy-saving Technology
Mở Rộng Kinh Doanh vào Thị Trường Châu Âu
Thành lập phòng thí nghiệm đẳng cấp thế giới
Đi đầu trong cuộc cách mạng Internet
Bắt Đầu Kinh Doanh Tại Mỹ
Theo con đường dẫn đến thành công thông qua công nghệ tiên tiến trong các hệ thống UPS, CyberPower đã đạt được thành công đáng kể ở Hoa Kỳ và Châu Âu, và đã tiếp tục mở rộng phạm vi dịch vụ mới trên toàn thế giới. Với sự xuất sắc của kỹ sư giàu kinh nghiệm và tiêu chuẩn chất lượng, CyberPower đã trở thành công ty hàng đầu với tư cách là một trong những nhà sản xuất bảo vệ năng lượng đang phát triển nhanh chóng trong ngành CNTT.
Hơn 100 nhà phân phối và điểm bán lẻ trên toàn thế giới
Đoạt giải Data Center 100 và TOP 20 Nhà Cung Cấp Cơ Sở Hạ Tầng Hàng Đầu của CRN ba lần liên tiếp kể từ năm 2013
CyberPower được CRN, một tạp chí hàng đầu của nhà cung cấp giải pháp và kênh CNTT, là một trong những nhà cung cấp dịch vụ trung tâm dữ liệu quan trọng hỗ trợ các công cụ sao lưu, giải pháp ảo hóa và lưu trữ đám mây từ các khía cạnh của cách cư xử hiệu quả và thân thiện với môi trường.
Nhận được chứng chỉ Energy Star đầu tiên trên thế giới từ nhóm CSA và được Chương trình Giải thưởng thực hành CNTT xanh tốt nhất năm 2012 trao giải Hệ thống CNTT hiệu quả năng lượng
Ra mắt dòng sản phẩm hệ thống UPS Trung tâm dữ liệu và phát triển khả năng tương thích phần mềm với các đối tác công nghệ ảo hóa quan trọng, bao gồm VMware, Hyper-V, Red Hat và Citrix
Với nhiều năm hoạt động thực tế và luôn cần cù trong lĩnh vực bảo vệ quá điện năng, CyberPower đã được công nhận cho khả năng chuyên môn về giải pháp doanh nghiệp.
Thành lập văn phòng tại Nhật Bản và bắt đầu bán hàng thông qua các kênh bán hàng tại Úc để mở rộng sự hiện diện tại khu vực Châu Á - Thái Bình Dương
CyberPower bắt đầu phát hành cổ phiếu ra công chúng (IPO) tại thị trường cổ phiếu Đài Loan
Công nghệ CyberPower GreenPower UPS™ đại diện cho nhiều thiết kế tiết kiệm năng lượng tiên tiến giúp cải thiện hiệu suất vận hành và loại bỏ tình trạng tiêu thụ năng lượng lãng phí.
Ra mắt UPS tần số tiết kiệm năng lượng cao đầu tiên với công nghệ cực kỳ hiệu quả
Được công nhận là ''Nhà cung cấp mới tốt nhất của năm'' bởi Ingram Micro, nhà phân phối máy tính và các sản phẩm công nghệ lớn nhất thế giới
Hoạt động kinh doanh của CyberPower tiếp tục nở rộ mạnh mẽ ở các kênh bán lẻ tại Mỹ và sau đó mở rộng ra thị trường Châu Âu.
Phát triển và ra mắt DC UPS cho ngành viễn thông
Bắt đầu hợp tác với nhà phân phối CNTT lớn nhất thế giới và nhà cung cấp công nghệ mạng toàn cầu, Tech Data và Tellabs
CyberPower phấn đấu để tăng cường hơn nữa khả năng nghiên cứu và phát triển bằng cách thành lập các phòng thí nghiệm nội bộ.
Được chứng nhận bởi UL LCC về việc cung cấp môi trường thử nghiệm tiên tiến
Tiến hành các thử nghiệm an toàn, chứng nhận EMI và thử nghiệm trước để thúc đẩy quá trình phát triển và nâng cao tính vượt trội kỹ thuật
CyberPower được chứng nhận là nhà cung cấp UPS tương thích Microsoft Windows 98 đầu tiên trên thế giới. '' Sau đó, tất cả các sản phẩm của UPS được thiết kế để tương thích với Microsoft OS, cho thấy sự quan sát sâu sắc của CyberPower về xu hướng và sự linh hoạt của chúng tôi để thích nghi và áp dụng mới Công nghệ.
Giới thiệu UPS Power98, UPS đầu tiên được thiết kế tương thích với Windows 98
Đã tiến vào các cửa hàng bán lẻ đa quốc gia và lớn nhất thế giới như: Walmart, BestBuy và Fry's
Với chuyên môn về bảo vệ quá điện năng và nguồn pin dự phòng, CyberPower đã bước chân vào hoạt động kinh doanh UPS tại thị trường Hoa Kỳ.
Trang web này sử dụng cookies để cung cấp cho bạn dịch vụ nhanh và phù hợp với nhu cầu cá nhân hơn. Khi sử dụng trang web này, bạn đã đồng ý với việc sử dụng cookie của chúng tôi. Tìm hiểu thêm về chúng tôiChính Sách Cookies.
Bằng cách đóng trang này, bạn xác nhận rằng trải nghiệm của bạn trên trang web của chúng tôi có thể bị giảm.
Tìm số sê-ri sản phẩm CyberPower của bạn
Các sản phẩm CyberPower đều có một số serial duy nhất (S/N) và chúng chỉ có thể có 12 hoặc 16 chữ số.
Vị trí của nhãn số serial có thể khác nhau tùy theo các sản phẩm khác nhau, nhưng bạn có thể tìm thấy nó ở mặt sau hoặc mặt dưới của hầu hết các sản phẩm.
Yêu cầu đặt lại mật khẩu của bạn đã được gửi. Một email có hướng dẫn sẽ được gửi đến hộp thư của bạn. Nếu không nhận được email, vui lòng kiểm tra thư mục thư rác hoặc thư rác
CyberPower makes no representation or warranty as to the accuracy, completeness or authenticity of the information contained in any such hypertext link or other Internet site, and access to any other Internet sites linked to the CyberPower site is at your own risk.
Xin lỗi, không có kết quả nào được tìm thấy dựa trên lựa chọn bộ lọc hiện tại của bạn. Vui lòng điều chỉnh giá trị và thử lại.Chỉ số tải điện chỉ có thể là con số. Xin lưu ý con số không bao giờ bằng 0 hoặc âm.