ENVIRONMENT BACKGROUND
With servers running 24 hours everyday to process data, a data center devours larger amounts of power than any typical office building. To satisfy the demand of this power hungry environment, CyberPower's best-in-class three-phase Uninterruptible Power Supply presents unparalleled adaptability to meet different sizes of data centers, assuring maximum uptime of mission-critical equipment and services while reducing operating cost with energy-efficient technology.
RECOMMENDED CONFIGURATION
A data center requires maximum availability to maintain seamless operation of IT service. In order to support high-performance service 24x7x365 even under fault conditions, a data center often adopts dual power paths to dual-corded loads. Simply, every load receives power from two independent power sources, each of which is capable of supporting the entire system during a power source failure.
To meet such demand, CyberPower recommends dual power paths for a single server cabinet as follows: both power source paths originating from a generator-compatible Datacenter UPS. The two PDUs in the cabinet are then powered by Input Power #1 and Input Power #2 respectively, and distribute power to dual-corded loads. Single-corded equipment can also be integrated into the maximum availability environment by using CyberPower Auto Transfer Switches (ATS). The ATS is designed to switch between two power sources and can enhance power redundancy to equipment with a single power cord.
When one UPS fails, the other UPS will take over to provide power to loads, protecting both single and dual-corded equipment from downtime and ensuring continuous operation all the time.

KEY BENEFITS
Power Distribution Units
GREAT VERSATILITY
-
Flexible mounting
Available in horizontal and vertical mounting models for different rack configurations.
-
Efficient power deployment
Delivers electric power to multiple devices from a single source.
-
Load monitoring
Displays the overall energy consumption of connected devices.
POWER AVAILABILITY
-
Power redundancy
Metered/Switched ATS ensures continuous power to single-corded equipment with dual input design.
CERTIFICATIONS
-
ENERGY STAR®
Meets the strict ENERGY STAR® efficiency guidelines to contribute to environmental protection and achieve energy cost savings.
More -
VMware READY™
VMware Ready™ certificated PowerPanel Business Edition software allows virtual application on VMware servers, providing power status monitoring, management, graceful shutdown and real-time notification of power events.
This product is not available in your region.
Your web browser is no longer supported.
Please upgrade to a modern, fully supported browser for best performance of the site.
By closing this window you acknowledge that your experience on our website may be degraded.
Find the serial number on your CyberPower products

Every CyberPower product has a unique serial number (S/N) and they can only be 12 or 16 digits.
The location of the serial number label may vary by different products, but you can find it on the back or bottom side of most products.
Information

Are you sure you want to leave this page? The selected itmes will be cleared.
Restart Stay on this pageThanks for registering with us. An email has been sent to you with a link to activate your account. If you do not receive the email, please check your spam folder or contact us.
OKThis serial number is not for a qualifying product. Please check if the serial number is the same as that on your package box.
OKYour password reset request has been submitted. An email with instructions will be sent to your inbox. If not received, please check your email spam or junk folder.
OKThis product is not available in your region.