CyberPower VP1600ELCDoffers home and office users a reliable battery backup and safeguards office PCs and other electronic devices from surges, spikes, brownouts and other power incidents. Designed with GreenPower UPS™ Technology to improve UPS operating efficiency and to minimize its energy consumption, users can enjoy significant energy cost savings over conventional UPS systems. The UPS provides Automatic Voltage Regulation (AVR) to maintain safe voltage for connected equipment.
The UPS provides multifunctional LCD readout to display clear power and battery conditions. The product features data line protection with high-speed transmission to safeguard phones, network and communication equipment against surge/spike as well as supply 1Gbps speed to transmit data. The UPS is also compatible with PowerPanel Power Management Software to achieve real-time monitoring and configuration.
Features
Line-interactive UPS Topology
Generator Compatible
Automatic Voltage Regulation (AVR)
High-speed Ethernet Data Transmission
Surge and Spike Protection
PowerPanel Management Software
Energy Saving Technology
Simulated Sine Wave Output
LCD Status Display
USB Connectivity Port
Serial Connectivity Port
What's in the box
VP1600ELCD
UPS
USB Cable
User's Manual
Product Registration Card
*
Product contents may vary according to different regions.For detailed information, please refer to user's manual/quick start guide.
AWARDS & CERTIFICATION
MORE INFORMATION
General
Phase
Single Phase
Form Factor
Tower
UPS Topology
Line-interactive
Energy Saving Technology
GreenPower UPS™ Bypass Technology
Energy Star Qualified
Active PFC Compatibility
Input
Dual Power Inputs
Generator Compatibility
Yes
Nominal Input Voltage
(
Vac
)
230 ± 10%
Input Voltage Range
(
Vac
)
167 ~ 295
Input Voltage Range (At specific volt)
Adjustable Voltage Range
(
Vac
)
Input Frequency
(
Hz
)
50 ± 5
60 ± 5
Input Frequency Detection
Auto-sensing
Rated Input Current
(
A
)
6.96
Input Connector Type
IEC C14
Plug Style
Detachable Power Cord Plug Type
Schuko x 1
Power Cord Length (ft.)
5
Power Cord Length (m.)
1.5
Output
Capacity (VA)
1600
Capacity (VA) (At specific volt)
Capacity (Watts)
960
Capacity (Watts) (At specific volt)
On Battery Waveform
Simulated Sine Wave
On Battery Voltage(s)
(
Vac
)
230 ± 10%
On Battery Frequency
(
Hz
)
50 ± 1%
60 ± 1%
Automatic Voltage Regulation (AVR)
Single Boost, Single Buck
Overload Protection
Circuit Breaker
Outlet(s) - Total
5
Outlet Type
Schuko x 5
Outlet(s) - Battery & Surge Protected
4
Outlet(s) - Surge-Only Protected
1
Outlet(s) - Battery Backup
Outlet(s) - Extension
Outlet(s) - Widely Spaced
Outlet(s) - Critical Load (CL)
Outlet(s) - Non-Critical Load (NCL)
Outlet(s) - ECO Controlled Outlets (ECO Mode)
Typical Transfer Time
(
ms
)
4
USB Charging Port(s)
USB Charging Total Output
USB Charging Total Output
(
Watts
)
USB-A Charging Output
USB-C Charging Output
Battery
Runtime at Half Load
(
min
)
11
Runtime at Full Load
(
min
)
2
Typical Recharge Time
(
Hours
)
8
Quick Recharge Time
(
Hours
)
Start On Battery
Yes
User-replaceable
Yes - Qualified Personnel Only
Hot-swappable
Battery Type
Sealed Lead-acid
Replacement Battery Pack (RBP)
Replacement Battery Pack (RBP) Quantity
(
pcs
)
Compatible Extended Battery Module (EBM)
Max. EBM Quantity
(
pcs
)
Surge Protection & Filtering
Surge Suppression
(
Joules
)
450
EMI/RFI Filtration
Yes
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out
Phone Protection RJ11
Network Protection RJ45
Coax Protection RG6
Management & Communications
LCD Panel
Yes
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information
The external battery runtime information has already included the internal battery runtime of the UPS.
Runtime Disclaimer :
Runtimes based on testing fully-charged, new batteries at normal operating conditions. Runtime is approximate and varies based on battery age, level of charge at test, environment, and other variables.
CRN Data Center 100 and Top 20 Infrastructure Provider
Fast Growing with Enterprise Solution
GreenPower UPS™ Energy-saving Technology
Expanding the Business into European Market
Established World-class In-house Laboratory
Taking the Lead following the Internet Revolution
Started Business in the U.S.
Followed the path to success through its state-of-the-art technology in UPS systems, CyberPower has gained significant success in the United States and Europe, and has been further expanding its new service coverage throughout the world. With the outstanding engineer excellence and quality standards, CyberPower has become a dominant leader as one of the fast-growing power protection manufacturers in the IT industry.
More than 100 distributors and retail locations worldwide
Won Data Center 100 and Top 20 Infrastructure Provider by CRN three times in a row since 2013
CyberPower was recognized by CRN, a top news source for solution provider and the IT channel, to be one of the significant vendors of data center service provider supporting backup tools, virtual solutions, and cloud hosting from the aspects of efficient and environmental friendly manners.
Received the world's first Energy Star certificate from CSA group and was awarded Energy-efficient IT Systems by Green IT Best Practice Award 2012
Launched Datacenter UPS systems product line, and developed software compatibility with critical virtualization technology partners, including VMware, Hyper-V, Red Hat, and Citrix
With years of practice and diligence in the field of power protection, CyberPower was recognized by its expertise in enterprise solution.
Established office in Japan and started sales through channels in Australia to expand its business presences in Asia-Pacific region
CyberPower started Initial Public Offering (IPO) in Taiwan stock market
CyberPower GreenPower UPS™ technology represents multiple advanced energy-saving designs that improve the operating efficiency and eliminate waste energy consumption.
Launched the first high-frequency energy-saving UPS with ultra-efficient technology
Recognized as ''Best New Vendor of the Year'' by Ingram Micro, the world's largest distributor of computer and technology products
CyberPower's business continued to flourish in the U.S. retail channels and later expanded to the market in Europe.
Developed and launched DC UPS for Telecom industry
Commenced partnership with the world's largest IT distributor and global network technology provider, Tech Data and Tellabs
CyberPower strived to further enhance the research and development capability by establishing in-house laboratories.
Certified by UL LCC to provide advanced testing environment
Performed safety tests, EMI certification and pre-testing to accelerate the development process and enhance engineering excellence
CyberPower was certified as the world’s first ''Microsoft Windows 98 compatible UPS vendor.'' After that, all of the UPS products are designed to be compatible with Microsoft OS, showing CyberPower's acute observation on the trend and our flexibility to adapt and adopt new technology.
Introduced UPS Power98, the first UPS designed to be compatible with Windows 98
Entered the world's largest and multi-national retail stores: Walmart, BestBuy and Fry's
With the expertise in power protection and battery backup, CyberPower has set its cornertone in the UPS business in the U.S. market.
This site uses cookies to provide you with a more responsive and personalized service. By using this site you agree to our use of cookies. Learn more about ourCookies Policy.
Thanks for registering with us. An email has been sent to you with a link to activate your account. If you do not receive the email, please check your spam folder or contact us.
Your password reset request has been submitted. An email with instructions will be sent to your inbox. If not received, please check your email spam or junk folder.
CyberPower makes no representation or warranty as to the accuracy, completeness or authenticity of the information contained in any such hypertext link or other Internet site, and access to any other Internet sites linked to the CyberPower site is at your own risk.