PDU Buying Guide

What is a PDU?

A PDU, or power distribution unit, is a device with multiple outlets. It is designed to be installed in a standard rack, where its main function is to distribute reliable network power from utility power source or an uninterruptible power supply (UPS) to multiple devices. Besides basic power functionalities, some advanced PDU models also allow users to perform advanced power monitoring.

市电
OR
不间断电源系统
Input
Input
PDU
Output
服务器

Why Do I Need a PDU?

As a company grows, the demand for more power and IT equipment will continue to rise. It is essential to find a power solution that can provide more electrical outlets catering to the increasing power needs.

The power usage effectiveness (PUE) metric has become an important measurement standard for reporting energy performance of data centers. An advanced PDU can provide accurate power measurement data and precise individual outlet metering that can help in the measuring of energy efficiency in data centers.

5 Things to Consider When Choosing the PDU

1. What type of a PDU do I need?

The series listed below are the common categories of PDU on the market, with their functions ranging from basic power distribution to advanced power monitoring and management. Be sure to identify your application before selecting the suitable model.

Power Distribution
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Local Monitoring
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Remote Monitoring(Unit-level)
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Remote Monitoring(Outlet-level)
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Remote Management(Outlet-level)
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Power Redundancy
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
Basic
Metered
Monitored
Switched
Metered-by-Outlet
Switched Metered-by-Outlet
Metered ATS
Switched ATS
2. How to estimate the PDU power capacity?

A PDU can be selected to distribute output power from a UPS, utility power or a generator to support all connected devices. Thus, it is important to figure out the power consumption of the devices.

Generally, the power of PDU is rated in amperage. If the power information of connected device is given in watts instead of amps, simply divided the watts by voltage to get an amps figure. Then, add up the total amperage of all your equipment, and choose a PDU with maximum input current higher than the power demand to avoid overloading.

3. What kind of input connector does the PDU need?

The input connector types may vary according to different regions, input voltage and current requirements. Choose the correct input connector based on your needs in order to utilize the PDU.

了解更多
4. What kind of outlets shall the PDU have?

Make sure to select the PDU models with suitable output receptacles for the connected devices. Additionally, it is recommended the number of PDU’s outlets exceeds the number of plugs you need for further expansion.

了解更多
5. Where to install the PDU?

The PDU can be mounted either horizontally or vertically. Below are the available installation types:

  • 0U Vertical Rackmount
  • 1U Vertical Rackmount
  • 1U Horizontal Rackmount
  • 2U Horizontal Rackmount

Consider the size of rack and the location to install the PDU when deciding on the form factors.

CyberPower PDU主要特色

高温环境下运作

PDU is typically mounted at the rear of a rack in the data center, which can experience extreme temperature, so it is important to select the device that can withstand harsh environments. CyberPower PDU can work under temperature as high as 45-60°C, ensuring normal operation for connected equipment.

Applied to:
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet
±1% 测量精准度

Generally, an accuracy of ±5% or less is considered to be acceptable for data center applications. Our advanced PDU provides trustworthy statistics, including values on voltages, currents or watts with ±1% measurement accuracy, allowing you to better calculate PUE (Power Usage Effectiveness) metrics to manage efficiency and performance within data centers.

Applied to:
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet
超低功耗

Reducing energy usage means decreasing the electricity costs. The PDU comes with ultra-low power consumption design, with typical power consumption of 4.5W, saving more than 80% of energy as compared to its competitors.

Applied to: *仅适用于部分型号
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet
可调式彩色 LCD 屏幕

Equipped with color LCD that can be configured by users, the product allows you to change the colors of the LCD screens, enabling convenient classification and identification of PDUs in data center application.

Applied to:
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet
可旋转的 LCD 屏幕

For proper viewing orientation, the product comes with automatic screen rotation, whether it is mounted vertically or horizontally in the rack.

Applied to:
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet
热插入 LCD 模块

To ensure easy maintenance without power interruption, the LCD is designed to be hot-swappable, which allows you to safely remove and replace LCD panel without having to shut down the system.

Applied to:
  • Basic
  • Metered
  • Monitored
  • Switched
  • Metered-by-Outlet
  • Switched Metered-by-Outlet

PDU FAQ

1. What is the difference between a PDU and a power strip?

While a PDU has similar basic functions as a power strip, a PDU provides more advanced options. For instance, a PDU allows users to monitor and control power remotely, or measure electrical usage in IT environment. For home or smaller offices, power strips may be adequate, but those who aims for larger company’s growth may enjoy the benefits of using a PDU.

2. Can the PDU monitor temperature and humidity?

Yes, with optional ENVIROSENSOR installed and connected, the PDU can monitor temperature and humidity in real time.

*仅适用于部分型号
Most Common Input Connector Types

See the following for some of the most common plug types among CyberPower PDU products.

NEMA 5-15P

NEMA 5-20P

NEMA L5-20P

NEMA L5-30P

NEMA L6-20P

NEMA L6-30P

IEC C14

IEC C20

IEC 60309 16A

IEC 60309 32A

Most Common Outlet Types

Here are some of the commonly output receptacles among CyberPower PDU products.

NEMA 5-15R

NEMA 5-20R

NEMA L5-20R

NEMA L5-30R

NEMA L6-20R

NEMA L6-30R

IEC C13

IEC C19

您的网页浏览器不支持此页面

为了呈现最优化的网站内容,请升级您的网页浏览器

关闭窗口

请注意,如果关闭此窗口,您在此网站的浏览效果将受影响

查询CyberPower产品序号

每款 CyberPower 产品都拥有唯一的序列号 (S/N),由12或16个英文字母及数字组成。

序列号标签位置可能因产品而异,但一般可以在产品的背面或者底部找到。

关闭窗口

相关信息

您确定要变更产品线吗?目前所选取的项目将会被取消。

确认 取消

您已超过比较数量上限。

OK

产品比较请选择相同产品线

OK
相关信息

产品比较表中已有数据,您要重新开始或继续?

重新开始 继续
相关信息

您确定要离开此页面吗?目前所选取的项目将被清除。

Restart Stay on this page
相关信息

此页面不适用于您所在的区域。

确认

请确实填写您的需求

确认

感谢您的注册,已向您发送了一封电子邮件,其中包含激活您帐号的链接。若您没有收到相关邮件,请检查您的垃圾邮件文件夹或与我们联系。

OK
相关信息

您的账户已认证成功

确认
相关信息

连结已过期或失效。

确认

抱歉!无法辨识您的身份,请在试一次

OK

您的个人资料已更新完成。

OK
相关信息

无产品注册纪录。

确认

您的产品已注册成功。

OK

产品序号不符,请再次确认您的产品与外包装序号是否相同。

OK

如果您已有账户,我们会将重新设定密码的链接,寄到您指定的信箱内。

OK

连结已过期。

OK

您的密码已更新,请使用新的密码入。

OK

您目前使用的密码未通过认证。

OK

请选择类型

OK

请选择城市

OK

请输入关键词

OK
相关信息

相关产品讯息请与当地代理或经销商联系

确认

序号重复

OK
相关信息

本次問卷已成功送出,我們的專員將會與您聯繫,謝謝。

确认
相关信息
相关信息

请登录注册您的产品。

继续
相关信息

请选择产品线

确认
请检查以上必填字段:
OK

Your message has been sent successfully.

OK

Your message send failed.

OK

请输入产品名称

OK

OK
    OK

    您的信息已经提交成功。

    OK

    提交成功,将自动开始下载。

    确认

    Your message send failed.

    OK

    此商品未在您所在的地区贩卖

    若您对此商品感兴趣,请与我们联系获得更多信息。联络窗口

    未抓到對應影片連結,請至Download Center檢查影片連結設定是否正確

    确认
    Service Notice
    OK

    此商品未在您所在的地区贩卖

    若您对此商品感兴趣,请与我们联系获得更多信息。|联络窗口

    此解决方案未在您所在的区域贩卖。

    若您对此解决方案感兴趣,请与我们联系获得更多信息。|联络窗口

    Please fill out all fields before submitting.

    确认
    设定新密码