CyberPower OLS10000ECguarantees power backup protection for multimedia devices, IT equipment, computers, workstations, NAS/Storage devices, telecom devices, networking devices, security/emergency systems, and surveillance systems. The UPS adopts double-conversion topology to provide high-quality power output with additional ECO Mode to conserve power and save on energy costs. The product is also compatible with generators to prolong power continuity.
To extend battery lifetime, the UPS adopts Smart Battery Management (SBM) to enhance battery charging process and achieve a lower total cost of ownership. The model also allows users to perform real-time monitoring and management via PowerPanel Power Management Software.
Features
Online (Double Conversion) UPS Topology
Generator Compatible
Zero Transfer Time
Surge and Spike Protection
LED Status Indicator
ECO Mode
Overload Protection
Smart Battery Management (SBM)
EMI and RFI Filtration
PowerPanel Management Software
What's in the box
OLS10000EC
UPS
USB Cable
User's Manual (Download from Website)
E-warranty Card
*
Product contents may vary according to different regions.For detailed information, please refer to user's manual/quick start guide.
AWARDS & CERTIFICATION
MORE INFORMATION
General
Phase
Single Phase
Form Factor
Tower
UPS Topology
Online Double Conversion
Energy Saving Technology
ECO Mode Efficiency > 96%
Energy Star Qualified
Active PFC Compatibility
Yes
Input
Dual Power Inputs
Generator Compatibility
Yes
Nominal Input Voltage
(
Vac
)
220
Input Voltage Range
(
Vac
)
110 ~ 276
Input Voltage Range (At specific volt)
Adjustable Voltage Range
(
Vac
)
0~80% Load for110 ~ 276 Vac
0~100% Load for176 ~ 276 Vac
Input Frequency
(
Hz
)
60 ± 6
50 ± 5
Input Frequency Detection
Auto-sensing
Rated Input Current
(
A
)
45.5
Input Power Factor
0.99
Backfeed Protection Connector
Input Connector Type
Hardwire Terminal Block
Plug Style
Detachable Power Cord Plug Type
Power Cord Length (ft.)
Power Cord Length (m.)
Output
Capacity (VA)
10000
Capacity (VA) (At specific volt)
Capacity (Watts)
8000
Capacity (Watts) (At specific volt)
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s)
(
Vac
)
208 ± 1%
220 ± 1%
230 ± 1%
240 ± 1%
Output Voltage Setting
Configurable
On Battery Frequency
(
Hz
)
60 ± 0.1%
50 ± 0.1%
Output Frequency Setting
Configurable
Power Factor
0.8
ECO Mode Voltage Tolerance
± 10 %
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse
Overload Protection (Line Mode)
105~125% Load for 1 min, 125~135% Load for 30 sec, 135~150% Load for 1 sec, >150% Load Immediately
Overload Protection (Battery Mode)
105~125% Load for 1 min, 125~135% Load for 30 sec, >135% Load Immediately
Overload Protection (Bypass Mode)
125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<2%
Harmonic Distortion (Non-linear Load)
THD<5%
Internal Bypass
Automatic Bypass
Maintenance Bypass
Outlet(s) - Total
1
Outlet Type
Hardwire Terminal Block x 1
Outlet(s) - Battery & Surge Protected
Outlet(s) - Surge-Only Protected
Outlet(s) - Battery Backup
Outlet(s) - Extension
Outlet(s) - Widely Spaced
Outlet(s) - Critical Load (CL)
Outlet(s) - Non-Critical Load (NCL)
Typical Transfer Time
(
ms
)
0
USB Charging Port(s)
USB Charging Total Output
USB Charging Total Output
(
Watts
)
USB-A Charging Output
USB-C Charging Output
Battery
Runtime at Half Load
(
min
)
11.2
Runtime at Full Load
(
min
)
3.9
Typical Recharge Time
(
Hours
)
9
Quick Recharge Time
(
Hours
)
Maximum Charging Current
(
A
)
1
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
User-replaceable
No
Hot-swappable
Battery Type
Sealed Lead-acid
Replacement Battery Pack (RBP)
Replacement Battery Pack (RBP) Quantity
(
pcs
)
Battery Quantity (Each RBP)
(
pcs
)
Battery Voltage (Each RBP)
(
V
)
Compatible Extended Battery Module (EBM)
Max. EBM Quantity
(
pcs
)
Surge Protection & Filtering
Surge Suppression
(
Joules
)
445
EMI/RFI Filtration
Yes
Phone/Network Protection RJ11/RJ45 (Combo)
Phone Protection RJ11
Network Protection RJ45
Coax Protection RG6
Management & Communications
LCD Panel
LCD Orientation
LCD Information Display
LCD Setting & Control
LED Indicators
Power On, Line Mode, Battery Mode, Bypass Mode, Battery Capacity, Low Battery, Overload, UPS Fault
*Runtimes based on testing fully-charged, new batteries at normal operating conditions. Runtime is approximate and varies based on battery age, level of charge at test, environment, and other variables.
**The external battery runtime information has already included the internal battery runtime of the UPS.
*Depending on the electrical input and output voltages of the UPS, efficiency and energy consumption data are measured according to ENERGY STAR or U.S. DoE test methods. These data are approximate and may vary based on the type and load of connected devices, power cord length, and other variables.
CRN Data Center 100 and Top 20 Infrastructure Provider
Fast Growing with Enterprise Solution
GreenPower UPS™ Energy-saving Technology
Expanding the Business into European Market
Established World-class In-house Laboratory
Taking the Lead following the Internet Revolution
Started Business in the U.S.
Followed the path to success through its state-of-the-art technology in UPS systems, CyberPower has gained significant success in the United States and Europe, and has been further expanding its new service coverage throughout the world. With the outstanding engineer excellence and quality standards, CyberPower has become a dominant leader as one of the fast-growing power protection manufacturers in the IT industry.
More than 100 distributors and retail locations worldwide
Won Data Center 100 and Top 20 Infrastructure Provider by CRN three times in a row since 2013
CyberPower was recognized by CRN, a top news source for solution provider and the IT channel, to be one of the significant vendors of data center service provider supporting backup tools, virtual solutions, and cloud hosting from the aspects of efficient and environmental friendly manners.
Received the world's first Energy Star certificate from CSA group and was awarded Energy-efficient IT Systems by Green IT Best Practice Award 2012
Launched Datacenter UPS systems product line, and developed software compatibility with critical virtualization technology partners, including VMware, Hyper-V, Red Hat, and Citrix
With years of practice and diligence in the field of power protection, CyberPower was recognized by its expertise in enterprise solution.
Established office in Japan and started sales through channels in Australia to expand its business presences in Asia-Pacific region
CyberPower started Initial Public Offering (IPO) in Taiwan stock market
CyberPower GreenPower UPS™ technology represents multiple advanced energy-saving designs that improve the operating efficiency and eliminate waste energy consumption.
Launched the first high-frequency energy-saving UPS with ultra-efficient technology
Recognized as ''Best New Vendor of the Year'' by Ingram Micro, the world's largest distributor of computer and technology products
CyberPower's business continued to flourish in the U.S. retail channels and later expanded to the market in Europe.
Developed and launched DC UPS for Telecom industry
Commenced partnership with the world's largest IT distributor and global network technology provider, Tech Data and Tellabs
CyberPower strived to further enhance the research and development capability by establishing in-house laboratories.
Certified by UL LCC to provide advanced testing environment
Performed safety tests, EMI certification and pre-testing to accelerate the development process and enhance engineering excellence
CyberPower was certified as the world’s first ''Microsoft Windows 98 compatible UPS vendor.'' After that, all of the UPS products are designed to be compatible with Microsoft OS, showing CyberPower's acute observation on the trend and our flexibility to adapt and adopt new technology.
Introduced UPS Power98, the first UPS designed to be compatible with Windows 98
Entered the world's largest and multi-national retail stores: Walmart, BestBuy and Fry's
With the expertise in power protection and battery backup, CyberPower has set its cornertone in the UPS business in the U.S. market.
This site uses cookies to provide you with a more responsive and personalized service. By using this site you agree to our use of cookies. Learn more about ourCookies Policy.
Thanks for registering with us. An email has been sent to you with a link to activate your account. If you do not receive the email, please check your spam folder or contact us.
Your password reset request has been submitted. An email with instructions will be sent to your inbox. If not received, please check your email spam or junk folder.
CyberPower makes no representation or warranty as to the accuracy, completeness or authenticity of the information contained in any such hypertext link or other Internet site, and access to any other Internet sites linked to the CyberPower site is at your own risk.
Sorry, there are no results found based on your current selection of filters. Please adjust the value and try again.Power load should be number only. Please note the number can't be zero or minus.
New password does not match.The password cannot be shorter than 8 characters.The password cannot be longer than 64 characters.Your current password is not authenticated.