VA60000Watts54000Rated Input Current
(
A
)
83Rated Output Voltage
(
Vac
)
Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 VacOutletsHardwire Terminal Block x 1
CyberPower HSTP3T60KE3-Phase online UPS provides long-lasting power backup for data closets, transportation and infrastructure, and emergency systems. With parallel redundancy capability, the HSTP3T (3-Phase) Series UPS is ideal for critical applications in server rooms, data centers, industrial factories, and power generation plants that require high capacity, high reliability, and extended runtimes.
With integrated IGBT technology and intelligent DSP-based control, the UPS produces less input total harmonic distortion (THDi) and achieves higher power efficiency up to 98% in Economy Mode, making it the most efficient UPS in the industry. Higher operating efficiency equates to lowered BTU heat dissipation and lowered idle power consumption, resulting in an operating expense reduction and a lower carbon footprint.
To improve operating efficiency, the UPS system works in bypass mode under normal conditions, during which the inverter is kept on standby. During power failures, the UPS switches to battery mode and the inverter continuously supplies the critical load to the connected equipment.
Features
Three-phase Design
Hot-swappable Power Modules
LCD Touch Panel
UPS Parallel Expansion
Generator Compatible
Overload Protection
LCD Status Display
SNMP/HTTP Remote Management Capability (Optional)
Online (Double Conversion) UPS Topology
ECO Mode
Color LCD Panel
Dual Inputs
Pure Sine Wave Output
Maintenance Bypass Switch
Emergency Power Off (EPO) Port
PowerPanel Management Software
What's in the box
HSTP3T60KE
User's Manual
*
Product contents may vary according to different regions.For detailed information, please refer to user's manual/quick start guide.
AWARDS & CERTIFICATION
MORE INFORMATION
General
Phase
Three Phase
Form Factor
Tower
UPS Topology
Online Double Conversion
Energy Saving Technology
ECO Mode Efficiency > 98%
Hot Swappable Bypass Module
Normal Mode Efficiency
(
%
)
95%
Battery Mode Efficiency
(
%
)
95%
Energy Star Qualified
Active PFC Compatibility
Yes
Redundancy Design
Parallel Expansion (Max. Units)
4
Input
Dual Power Inputs
Yes
Generator Compatibility
Yes
Nominal Input Voltage
(
Vac
)
Input Voltage Range
(
Vac
)
Nominal Input Voltage
(
Vac
)
Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac
Input Voltage Range
(
Vac
)
Line to Neutral (L-N):132 ~ 276 Vac
Line to Line (L-L):228 ~ 478 Vac
Configurable Voltage Range
(
Vac
)
Line to Neutral (L-N):220 ~ 250 Vac
Line to Line (L-L):380 ~ 435 Vac
Default Input Voltage Range (Bypass)
Configurable Input Voltage Range (Bypass Mode)
Input Frequency
(
Hz
)
50 ± 3
60 ± 3
Input Frequency (Configurable)
(
Hz
)
Input Frequency Range
(
Hz
)
40 ~ 70
Default Frequency Tolerance (Bypass)
Configurable Frequency Tolerance (Bypass)
Rated Input Current
(
A
)
83
Rated Input Current (Bypass)
Current Harmonic
(
%
)
THDI (%)
THDI (%)
Input Power Factor
0.99
Backfeed Protection
Overload Protection (Bypass)
Bypass to Inverter Switch Time
(
ms
)
Current Rating of Neutral Cable (Bypass)
(
A
)
Synchronization Window (Nominal)
(
Hz
)
Synchronization Window (Configurable)
Input Connector
Input Connector Type
Hardwire Terminal Block
Plug Style
Detachable Power Cord Plug Type
Power Cord Length (ft.)
Power Cord Length (m.)
Output
Capacity (VA)
60000
Capacity (Watts)
54000
On Battery Waveform
Pure Sine Wave
Output Voltage Setting
Configurable
Output Frequency Setting
Configurable
Rated Output Voltage
(
Vac
)
Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac
Output Voltage Range
(
Vac
)
Output Voltage Tolerance
(
%
)
1.5%
Output Frequency
(
Hz ± %
)
50 ± 0.1
60 ± 0.1
Output Frequency
(
Hz ± %
)
Power Factor
0.9
Automatic Voltage Regulation (AVR)
Voltage Regulation
ECO Mode Voltage Tolerance
± 10 %
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse
Overload Protection (Line Mode)
105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately
Overload Protection (Battery Mode)
105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately
Overload Protection (Bypass Mode)
125~130% Load for 10 min, 130~150% Load for 1 min, 150~400% Load for 1 sec, >400% Load Immediately
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<1%
Harmonic Distortion (Non-linear Load)
THD<5.5%
Internal Bypass
Automatic Bypass, Manual Bypass
Maintenance Bypass
Yes
Max Change Rate of Sync Frequency (Default)
(
Hz/sec
)
Change Rate Range of Sync Frequency (Configurable)
(
Hz/sec
)
Neutral Current Capability
(
%
)
Non-Linear Load Capability
(
%
)
Short Circuit Protection
Synchronization Window (Nominal)
(
Hz
)
Synchronization Window (Configurable)
Output Connector
Outlet(s) - Total
Outlet Type
Hardwire Terminal Block x 1
Outlet(s) - Battery & Surge Protected
Outlet(s) - Surge-Only Protected
Outlet(s) - Battery Backup
Outlet(s) - Extension
Outlet(s) - Widely Spaced
Outlet(s) - Critical Load (CL)
Outlet(s) - Non-Critical Load (NCL)
Typical Transfer Time
(
ms
)
0
USB Charging Port(s)
USB Charging Current
Battery
Runtime at Half Load
(
min
)
Runtime at Full Load
(
min
)
Runtime at Half Load (For Specific Battery)
Runtime at Full Load (For Specific Battery)
Typical Recharge Time
(
Hours
)
Quick Recharge Time
(
Hours
)
Maximum Charging Current
(
A
)
Typical Charging Current
(
A
)
Maximum Discharge Current
(
A
)
Ripple Current
Compatible Battery Types
VRLA, AGM, Gel, Wet
Recharge Power
(
%
)
Default 10% (Selectable from 1~20% x UPS Capacity)
*Depending on the electrical input and output voltages of the UPS, efficiency and energy consumption data are measured according to ENERGY STAR or U.S. DoE test methods. These data are approximate and may vary based on the type and load of connected devices, power cord length, and other variables.
CRN Data Center 100 and Top 20 Infrastructure Provider
Fast Growing with Enterprise Solution
GreenPower UPS™ Energy-saving Technology
Expanding the Business into European Market
Established World-class In-house Laboratory
Taking the Lead following the Internet Revolution
Started Business in the U.S.
Followed the path to success through its state-of-the-art technology in UPS systems, CyberPower has gained significant success in the United States and Europe, and has been further expanding its new service coverage throughout the world. With the outstanding engineer excellence and quality standards, CyberPower has become a dominant leader as one of the fast-growing power protection manufacturers in the IT industry.
More than 100 distributors and retail locations worldwide
Won Data Center 100 and Top 20 Infrastructure Provider by CRN three times in a row since 2013
CyberPower was recognized by CRN, a top news source for solution provider and the IT channel, to be one of the significant vendors of data center service provider supporting backup tools, virtual solutions, and cloud hosting from the aspects of efficient and environmental friendly manners.
Received the world's first Energy Star certificate from CSA group and was awarded Energy-efficient IT Systems by Green IT Best Practice Award 2012
Launched Datacenter UPS systems product line, and developed software compatibility with critical virtualization technology partners, including VMware, Hyper-V, Red Hat, and Citrix
With years of practice and diligence in the field of power protection, CyberPower was recognized by its expertise in enterprise solution.
Established office in Japan and started sales through channels in Australia to expand its business presences in Asia-Pacific region
CyberPower started Initial Public Offering (IPO) in Taiwan stock market
CyberPower GreenPower UPS™ technology represents multiple advanced energy-saving designs that improve the operating efficiency and eliminate waste energy consumption.
Launched the first high-frequency energy-saving UPS with ultra-efficient technology
Recognized as ''Best New Vendor of the Year'' by Ingram Micro, the world's largest distributor of computer and technology products
CyberPower's business continued to flourish in the U.S. retail channels and later expanded to the market in Europe.
Developed and launched DC UPS for Telecom industry
Commenced partnership with the world's largest IT distributor and global network technology provider, Tech Data and Tellabs
CyberPower strived to further enhance the research and development capability by establishing in-house laboratories.
Certified by UL LCC to provide advanced testing environment
Performed safety tests, EMI certification and pre-testing to accelerate the development process and enhance engineering excellence
CyberPower was certified as the world’s first ''Microsoft Windows 98 compatible UPS vendor.'' After that, all of the UPS products are designed to be compatible with Microsoft OS, showing CyberPower's acute observation on the trend and our flexibility to adapt and adopt new technology.
Introduced UPS Power98, the first UPS designed to be compatible with Windows 98
Entered the world's largest and multi-national retail stores: Walmart, BestBuy and Fry's
With the expertise in power protection and battery backup, CyberPower has set its cornertone in the UPS business in the U.S. market.
This site uses cookies to provide you with a more responsive and personalized service. By using this site you agree to our use of cookies. Learn more about ourCookies Policy.
Thanks for registering with us. An email has been sent to you with a link to activate your account. If you do not receive the email, please check your spam folder or contact us.
Your password reset request has been submitted. An email with instructions will be sent to your inbox. If not received, please check your email spam or junk folder.
CyberPower makes no representation or warranty as to the accuracy, completeness or authenticity of the information contained in any such hypertext link or other Internet site, and access to any other Internet sites linked to the CyberPower site is at your own risk.
Sorry, there are no results found based on your current selection of filters. Please adjust the value and try again.Power load should be number only. Please note the number can't be zero or minus.